In a CyberNewsFlash issued on 19 November 2026, Japan's JPCERT/CC said VulnCheck observed attackers exploiting CVE-2026-58115 to register malicious flows on Node-RED instances without authentication (adminAuth), run OS commands and attempt to download and run malicious programs, and that unauthenticated Node-RED instances are being automatically scanned for and exploited [1][2]. The flaw is a missing-authentication vulnerability (CWE-306, CVSS 10.0) in Node-RED on Siemens SIMATIC IoT2050 Advanced/Basic/M.2/SM disclosed by Siemens on 11 August 2026; IFIN separately reported crypto miners, RATs, botnet malware and rootkit shared libraries on exposed Node-RED instances, and JPCERT/CC has received reports of hosts in Japan being targeted [1][3][4]. What to do now: JPCERT/CC advises following the official "Securing Node-RED" guide to enable HTTPS, require authentication on the editor and admin API and protect HTTP nodes, and to use the VulnCheck and IFIN IoCs to check for suspicious flows, OS command execution, unusual outbound traffic and malware [1].
Node-RED instances without authentication are automatically scanned and loaded with malicious flows: CVE-2026-58115 exploited, hosts in Japan targeted
4 min readLast updated
30-second summary
What happened
Who is affected
Organisations running: Siemens SIMATIC IoT2050 Advanced, Siemens SIMATIC IoT2050 Basic, Siemens SIMATIC IoT2050 M.2, Siemens SIMATIC IoT2050 SM
What to do now
- Disclosed
- Aug 11, 2026
- Published
- Nov 20, 2026
- Last updated
- Nov 19, 2026
- CVSS basis
- Our assessment
- 1%, higher than 60% of CVEs
- Technology
- Attack vector
- Impact
- Vulnerability status
- Actor type
- Motivation
On this page
Affected scope
| Affected scope | Versions | Fixed in | |
|---|---|---|---|
| Siemens SIMATIC IoT2050 Advanced | Industrial OS(已安裝 Node-RED)V4.3.4-1 之前所有版本;Example Image(已安裝 Node-RED)所有版本[4] | V4.3.4-1(僅 Industrial OS;Example Image 目前無修補) | ✓ Patched |
| Siemens SIMATIC IoT2050 Basic | Industrial OS(已安裝 Node-RED)V4.3.4-1 之前所有版本;Example Image(已安裝 Node-RED)所有版本[4] | V4.3.4-1(僅 Industrial OS;Example Image 目前無修補) | ✓ Patched |
| Siemens SIMATIC IoT2050 M.2 | Industrial OS(已安裝 Node-RED)V4.3.4-1 之前所有版本;Example Image(已安裝 Node-RED)所有版本[4] | V4.3.4-1(僅 Industrial OS;Example Image 目前無修補) | ✓ Patched |
| Siemens SIMATIC IoT2050 SM | Industrial OS(已安裝 Node-RED)V4.3.4-1 之前所有版本;Example Image(已安裝 Node-RED)所有版本[4] | V4.3.4-1(僅 Industrial OS;Example Image 目前無修補) | ✓ Patched |
Timeline
Technical details
What Happened
On November 19, 2026, JPCERT/CC released a CyberNewsFlash reporting that VulnCheck had observed exploitation attempts leveraging CVE-2026-58115 on November 2, 2026: attackers registered malicious flows on a vulnerable host prepared by VulnCheck, executed OS commands via the flows, and attempted to download and execute . VulnCheck also noted that Node-RED instances without authentication (adminAuth) configured for the editor and management API are undergoing automated discovery and exploitation [1]. JPCERT/CC stated that it has received reports of Node-RED hosts in Japan being targeted by attacks exploiting this vulnerability [1].
Vulnerability Details
On August 11, 2026, Siemens published SSA-834709, explaining that SIMATIC IoT2050 devices running Node-RED do not enforce authentication on the Node-RED HTTP interface. Unauthenticated remote attackers can create malicious flows via the HTTP interface to execute arbitrary code on the underlying server with maximum privileges. Both v3.1 and v4.0 base scores are 10.0, and the vulnerability type is CWE-306 [4]. Siemens updated its advisory on November 4 and November 10, 2026, with the latter adding additional affected configurations in the SIMATIC IoT2050 series [4]. VulnCheck and JPCERT/CC noted that other products embedding Node-RED without adminAuth configured may be similarly affected [1].
Attack Vector
VulnCheck reported that its honeypot captured an attacker deploying a flow via a single POST /flows request on October 30, 2026, where an inject node automatically triggered an exec node to run base64-encoded commands, downloading from , saving it to , and executing it. The same source IP, (Microsoft AS8075), launched 16 attacks targeting this between October 30 and November 1 . VulnCheck noted that its honeypots did not observe exploitation targeting Siemens products, and it has added this CVE to the VulnCheck (it was not yet listed in the CISA KEV at the time of writing) .
Remediation
Vendor guidance
- 1
- 2
- 3
References
Official / primary2
- [1]
“JPCERT/CC has received reports that hosts running Node-RED domestically have been targeted by attacks exploiting this vulnerability.”
- [4]
Found this useful?
Pass it to whoever runs these systems so they can patch in time.
This site aggregates public information and is not security consulting advice. Test remediation steps before applying.